Solid fuel stove with a water circuit 10 kW

Solid fuel stove with a water circuit 10 kW
Solid fuel stove with a water circuit 10 kW Solid fuel stove with a water circuit 10 kW Solid fuel stove with a water circuit 10 kW
Product Code: AQUAB10
Availability: In Stock
Price: 0€
Price with VAT: 0€
Qty:     - OR -   Add to Wish List
Add to Compare

Buleryan furnace with a water circuit, in insulated enclosure is designed for heating residential and commercial premises

The furnace with heat-insulated enclosure is used when heat and coolant must be fully transmitted without loss in otopleniya.Pech buleryan with a water circuit, in insulated enclosure is designed for heating residential and commercial premises

The furnace with heat-insulated enclosure is used when heat and coolant must be completely lossless transferred to the heating system.

The original development of the company "Rud Ekzost Systems" - bulleryan with a water circuit.

For principled basis the classic, convection oven "bulleryan", working on the principle of afterburning furnace gas in the second chamber. Significant changes compared to the same heating unit, which generally have a lot of popularity in the CIS market. Our designers have studied all the advantages and disadvantages of furnace and boiler design made more perfect by supplying pre-heated primary and secondary air, increased the loading chamber, set the grate and ash pan added. Also, the heating unit is adapted to work with the automatic adjustment of the primary air supply, due to which it became possible for a long time to keep a constant flow temperature automatically.

Water boiler passed industrial tests and showed excellent results. The duration of the intensive heating of the coolant 12 hours at a load of wood, the duration of a complete combustion of the fuel load more than 24 hours.
It is safe to say that we presented to the market the country's innovative solid-long burning boiler. The great merit of the engineering corps of "Rude Ekzost System" is that we have a reliable heating unit, with original design, high efficiency and reasonable cost for the end user.
The boiler has a pipe structure, which allows to withstand high thermal and physical activity. By just such a design we have a large area of ​​contact with the metal cooled with combustion chambers, a quick exit in the boiler operation.

We use in seamless boiler tubes with a wall of 4 mm, which have the advantage of durability in comparison with a pipe seam. Sheet steel is used with a thickness of 4 mm, cast iron grate, wooden lacquered handles for easy and safe operation.

Option without insulation of the boiler body: used when the useful thermal energy released by the heating unit housing must remain in a heated room. For example: service, production facilities, etc.

Option with heat-insulated boiler body: is used when the heat of coolant should be fully and without losses transferred to the heating system. In the case where the heater is located in a separate boiler room in which there is no need to heat the room.

Option with automatic coolant temperature control: used for more economical operation of the heating system. It sets the required flow temperature and automatically adjusts the supply of heated primary air for optimizing fuel combustion.

Heat output, kW 21
The area of ​​heated space (H2,5m), 200 m2
Efficiency, at least 85
Volume of the loading chamber, 74 liters
The diameter of the combustion chamber door, 290 mm
Water loop volume, l 34.5
Connection thread for water inlet and outlet G 1-1 / 2 "
The maximum coolant temperature at the outlet 95 ° C
Minimum coolant inlet temperature, ° C 60
The diameter of the chimney pipe, mm, at least 150
The height of the chimney, m is not less than 6
Maximum length of firewood, mm, not more than 450
Max. fuel loading mass kg 35
fuel weight for optimum combustion mode, kg 8
Operating pressure, MPa 0.2
The maximum pressure of 0.3 MPa
Overall dimensions, mm
- Height, mm, no more
- Depth, mm, no more
- Width, mm, no more
960
610
650
Net Weight, kg, not more than 180
Recommended fuels, firewood, wood chips, briquettes, pellets, agro waste, waste wood, lignite fraction of at least 40 mm

Write a review

Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below:



Description

Buleryan furnace with a water circuit, in insulated enclosure is designed for heating residential and commercial premises

The furnace with heat-insulated enclosure is used when heat and coolant must be fully transmitted without loss in otopleniya.Pech buleryan with a water circuit, in insulated enclosure is designed for heating residential and commercial premises

The furnace with heat-insulated enclosure is used when heat and coolant must be completely lossless transferred to the heating system.

The original development of the company "Rud Ekzost Systems" - bulleryan with a water circuit.

For principled basis the classic, convection oven "bulleryan", working on the principle of afterburning furnace gas in the second chamber. Significant changes compared to the same heating unit, which generally have a lot of popularity in the CIS market. Our designers have studied all the advantages and disadvantages of furnace and boiler design made more perfect by supplying pre-heated primary and secondary air, increased the loading chamber, set the grate and ash pan added. Also, the heating unit is adapted to work with the automatic adjustment of the primary air supply, due to which it became possible for a long time to keep a constant flow temperature automatically.

Water boiler passed industrial tests and showed excellent results. The duration of the intensive heating of the coolant 12 hours at a load of wood, the duration of a complete combustion of the fuel load more than 24 hours.
It is safe to say that we presented to the market the country's innovative solid-long burning boiler. The great merit of the engineering corps of "Rude Ekzost System" is that we have a reliable heating unit, with original design, high efficiency and reasonable cost for the end user.
The boiler has a pipe structure, which allows to withstand high thermal and physical activity. By just such a design we have a large area of ​​contact with the metal cooled with combustion chambers, a quick exit in the boiler operation.

We use in seamless boiler tubes with a wall of 4 mm, which have the advantage of durability in comparison with a pipe seam. Sheet steel is used with a thickness of 4 mm, cast iron grate, wooden lacquered handles for easy and safe operation.

Option without insulation of the boiler body: used when the useful thermal energy released by the heating unit housing must remain in a heated room. For example: service, production facilities, etc.

Option with heat-insulated boiler body: is used when the heat of coolant should be fully and without losses transferred to the heating system. In the case where the heater is located in a separate boiler room in which there is no need to heat the room.

Option with automatic coolant temperature control: used for more economical operation of the heating system. It sets the required flow temperature and automatically adjusts the supply of heated primary air for optimizing fuel combustion.

Heat output, kW 21
The area of ​​heated space (H2,5m), 200 m2
Efficiency, at least 85
Volume of the loading chamber, 74 liters
The diameter of the combustion chamber door, 290 mm
Water loop volume, l 34.5
Connection thread for water inlet and outlet G 1-1 / 2 "
The maximum coolant temperature at the outlet 95 ° C
Minimum coolant inlet temperature, ° C 60
The diameter of the chimney pipe, mm, at least 150
The height of the chimney, m is not less than 6
Maximum length of firewood, mm, not more than 450
Max. fuel loading mass kg 35
fuel weight for optimum combustion mode, kg 8
Operating pressure, MPa 0.2
The maximum pressure of 0.3 MPa
Overall dimensions, mm
- Height, mm, no more
- Depth, mm, no more
- Width, mm, no more
960
610
650
Net Weight, kg, not more than 180
Recommended fuels, firewood, wood chips, briquettes, pellets, agro waste, waste wood, lignite fraction of at least 40 mm

Write a review

Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below: